Andrej Studen d2fcd1887e Update 'README.md' | 1 год назад | |
---|---|---|
slicerModules | 2 лет назад | |
slicerScripts | 1 год назад | |
utils | 3 лет назад | |
CMakeLists.txt | 5 лет назад | |
LICENSE | 5 лет назад | |
Labkey.png | 7 лет назад | |
README.md | 1 год назад | |
networkConfig.json.sample | 5 лет назад |
This package allows user to connect to a labkey server through a slicer interface.
Since there is no master
branch, git clone will report
warning: remote HEAD refers to nonexistent ref, unable to checkout.
Which is just a warning. Simply move to SlicerLabkeyExtension directory and checkout the SlicerExtensionIndex branch.
To use, add path to unpackaged labkeySlicerPythonAPI/labkeySlicerPythonExtension to Additional module paths in Slicer->Edit->Application Settings->Modules submenu. You'll also need the SlicerLabkeyDICOMtools package, also available from wiscgit.
Then the package will appear under LabKey.
If you are interested in the code, you should look at slicerNetwork.py which implements the communication with the server and forms HTTP Labkey API commands.
More details and tutorial can be found at: http://www-f9.ijs.si/~studen/blogs/posts/2017/May/31/slicerlabkey-integration/
A set of tools that provide DICOM loading from a remote, labkey controlled database. Most significant difference from native Slicer DICOM libraries is that no local database is used as the files are tracked by LabKey database, and that files do not neccesarily exist on local storage.
In particular, functions like load(self,net,path) are implemented where net referrs to the server setup (slicerNetwork instance of SlicerLabKeyPythonAPI) and path is a relative path to a remote file. Two implementations were made,
importDicom that uses pydicom. Use Connection button (blue frame) to specify connections,
add path on a specified LabKey site text box (cyan), provide filter as a JSON
object in a text file (gold) and a button to load the remote DICOM directory as a node (red).
Multiple nodes will be created if multiple DICOM series are in the target directory.
To select, use filter window and specify seriesUUID or similar tags. Minimal settings require a single
field with the content SeriesLabel
and a key which should be a valid DICOM tag name
with the first letter in small case.
loadDicom that is based on DICOMLib and Slicer embedded DCMTK tools. Using SlicerRT, the program is able to load contours from DICOM-RT files, started by pushing on the pink button. The green framed button loads mixed content of volumes and segmentations.
In particular workflows, vtkMRMLVolumeNodes created through data manipulation must be
stored remotely in DICOM format for validation in other image software tools (like review by
clinicans at dedicated work-stations). exportDicom
has a function exportNode, which
uploads a named node to a DICOM directory in LabKey, using unique UUID generated
from baseUUID that has to be provided by the user. Use services such as FreeDICOM to
generate your own unique UUID.